Identification and connections
Check UPS 15-50 A0 /FP and P/N 59965505 with the label of your Pump. Check the mouths of Hydraulic body, Air vent, Connector and fixings.

Circulation pump reconditioned Grundfos UPS 15-50 A0 /FP, catalogued for Ferroli New Elite F 30 E. The label identifies the P/N 59965505, 230 V power supply and three power powers: 35, 60 and 85 W. Compare also the Hydraulic body and Connector before choosing it.
The Pump drives the water from the Circuit to transport heat. The photo unit brings together Motor, Hydraulic body and Air vent; it is appropriate to compare the complete Assembly, because sharing the Motor model does not guarantee that hydraulic connections match.
The indication 35 / 60 / 85 W corresponds to the three electric power positions of the Motor. It does not express the thermal power of the Boiler or the Flow rate of water.
Transcribed data from the printed unit label. They are not measured values in an operating test.
Choose a photo of your part to view it beside this unit. Compare the labels, connectors and mounting points from the same angle.
Your photo stays on your device: it is not sent or stored.

The name Ferroli New Elite F 30 E matches both catalogues. Before purchasing, validates the variant by cutting the equipment and label of the Pump. The selection must also match the Hydraulic body, the fixations and the electric Connection.
No models are documented for that search.
Compare the Part label installed and the cutting of your variant before you buy.
Check UPS 15-50 A0 /FP and P/N 59965505 with the label of your Pump. Check the mouths of Hydraulic body, Air vent, Connector and fixings.
The lack of circulation can have several causes. The technician must check the power supply, the status of the Circuit and the operation of the Pump before attributing the fault.
The installation and testing of the equipment are carried out by a qualified technician.
We repair boilers in Madrid and the surrounding areas. Installation is arranged separately from the purchase of the part.
No. Compare the complete variant A0 /FP, the P/N and the Hydraulic body. Two pumps with the same Motor family may have different connections.
No. They are the electrical powers indicated for the three positions of the Pump. They are not kilowatts of Heating.